90
Trinix NXT — Installation and Service Manual
Section 9 — Planning Guide
would be a 512 x 512 pre-wired for expansion to 1024 x 1024 (similar to the
system that is shown in
). Only frame 0 would be
active in the 512 x 512 router, so only the port expanders connected to
Frame 0 would be in use. Frame 1’s inputs are connected to the top left PE;
while Frame 2’s outputs are connected to the top right PE. Therefore Frame
1’s
input
slots would require LD-33100s and Frame 2’s
output
slots would
require LD-33100s. No LD boards would be needed for Frame 3.
Monitoring with Expanded Systems
Symmetric Frame
Output monitor signals must be sent through a combiner in expanded sys-
tems. An example of an output-expanded system in shown in
; an input-expanded system is shown in (
Note
Output monitoring is not available for input-expanded systems controlled by
an SR-33000 Sync/OPM board.
Summary of Contents for TRINIX NXT -
Page 10: ...10 Trinix NXT Installation and Service Manual Preface ...
Page 26: ...26 Trinix NXT Installation and Service Manual Regulatory Notices ...
Page 30: ...30 Trinix NXT Installation and Service Manual ESD Protection ...
Page 120: ...120 Trinix NXT Installation and Service Manual Section 9 Planning Guide ...
Page 284: ...284 Trinix NXT Installation and Service Manual Section 12 Broadlinx Installation ...
Page 336: ...336 Trinix NXT Installation and Service Manual Section 14 Broadlinx Console Commands ...
Page 370: ...370 Trinix NXT Installation and Service Manual Section 16 Protected Paths ...
Page 436: ...436 Trinix NXT Installation and Service Manual Appendix 22 Trinix Frame Slot Maps ...
Page 440: ...440 Trinix NXT Installation and Service Manual Appendix 23 Expanded System Sizes ...