Installation and Service Manual389
Section
19
Troubleshooting
Note
It may take up to 30 seconds for the 3G modules alarms to clear when
starting up the boards. The boards are operational; however the voltage
sensing alarms can take up to 30 seconds to clear. This length of time to
clear the alarms is due to the fact that the 3G modules are using new
voltage averaging algorithms in the 908 Micro controllers to compare
and verify all voltages.
LEDs
Front panel
Power supplies
Legacy Frames
Display
Meaning
POWER/ALARM
Red
Master alarm for this frame: check internal alarm LEDs
Green
Power on, frame OK
Amber
Secondary warning: single fan failure or secondary NR board is active. Check
internal alarm LEDs
Note
Only in the Symmetrical frames.
Off
System is not powered
Display
Meaning
AC OK
Green
AC Power OK
Off
Supply is not powered (or is not operating)
DC OK
Green
DC power OK
Summary of Contents for TRINIX NXT -
Page 10: ...10 Trinix NXT Installation and Service Manual Preface ...
Page 26: ...26 Trinix NXT Installation and Service Manual Regulatory Notices ...
Page 30: ...30 Trinix NXT Installation and Service Manual ESD Protection ...
Page 120: ...120 Trinix NXT Installation and Service Manual Section 9 Planning Guide ...
Page 284: ...284 Trinix NXT Installation and Service Manual Section 12 Broadlinx Installation ...
Page 336: ...336 Trinix NXT Installation and Service Manual Section 14 Broadlinx Console Commands ...
Page 370: ...370 Trinix NXT Installation and Service Manual Section 16 Protected Paths ...
Page 436: ...436 Trinix NXT Installation and Service Manual Appendix 22 Trinix Frame Slot Maps ...
Page 440: ...440 Trinix NXT Installation and Service Manual Appendix 23 Expanded System Sizes ...