Trinix NXT — Installation and Service Manual
Section 19 — Troubleshooting
512 Matrix board - DM-33501/33502
Part side
Ref
Display
Meaning
IN USE A
DS201_1
Yellow
A CrossPoint is active in XPT_A IC
Off
No CrossPoints are active in XPT_A IC
P2V5A OK
DS204_1
Green
P2V5A converter is OK (for XPT_A side)
Off
P2V5A converter has failed
IN USE B
DS201_2
Yellow
A CrossPoint is active in XPT_B IC
Off
No CrossPoints are active in XPT_B IC
XC DONE
DS402
Green
FPGAs are configured
Off
FPGAs are not configured
ALARM
DS401
Red
One or more fault conditions exist
Off
Normal operation
P2V5B OK
DS204_2
Green
P2V5B converter is OK (for XPT_B side)
Off
P2V5B converter has failed
P5V
DS901
Green
Logic supply is OK
Off
Logic supply has failed
PS1 OK
-
Green
Main DC-DC Converter 1 is OK
Off
Main DC-DC Converter 1 has failed
PS2 OK
-
Green
Main DC-DC Converter 2 is OK
Off
Main DC-DC Converter 2 has failed
Summary of Contents for TRINIX NXT -
Page 10: ...10 Trinix NXT Installation and Service Manual Preface ...
Page 26: ...26 Trinix NXT Installation and Service Manual Regulatory Notices ...
Page 30: ...30 Trinix NXT Installation and Service Manual ESD Protection ...
Page 120: ...120 Trinix NXT Installation and Service Manual Section 9 Planning Guide ...
Page 284: ...284 Trinix NXT Installation and Service Manual Section 12 Broadlinx Installation ...
Page 336: ...336 Trinix NXT Installation and Service Manual Section 14 Broadlinx Console Commands ...
Page 370: ...370 Trinix NXT Installation and Service Manual Section 16 Protected Paths ...
Page 436: ...436 Trinix NXT Installation and Service Manual Appendix 22 Trinix Frame Slot Maps ...
Page 440: ...440 Trinix NXT Installation and Service Manual Appendix 23 Expanded System Sizes ...