350
Trinix NXT — Installation and Service Manual
Section 16 — Protected Paths
4.
Enter
deviceMasterShow
at the command prompt for both the
primary and secondary console connections. The Device Master
information will then be shown.
5.
Verify that the following values are the same on both boards:
•
Frames Added
•
Slaves Added
Figure 243. The Device Master Information List
If the values are the same, the Broadlinx board is ready to be initialized and
activated. If the values are not the same, contact Grass Valley’s Technical
support (