P a g e
|
371
UCM6200 Series User Manual
Version 1.0.20.38
Advanced Settings
FXO Opermode
Select country to set the On-Hook Speed, Ringer Impedance, Ringer
Threshold, Current Limiting, TIP/RING voltage adjustment, Minimum
Operational Loop Current, and AC Impedance as predefined for your country's
analog line characteristics. The default setting is "United States of America
(USA)".
FXS Opermode
Select country to set the On-Hook Speed, Ringer Impedance, Ringer
Threshold, Current Limiting, TIP/RING voltage adjustment, Minimum
Operational Loop Current, and AC Impedance as predefined for your country's
analog line characteristics. The default setting is "United States of America
(USA)".
FXS TISS Override
Configure to enable or disable override Two-Wire Impedance Synthesis
(TISS). The default setting is No.
If enabled, users can select the impedance value for Two-Wire Impedance
Synthesis (TISS) override. The default setting is 600Ω.
PCMA Override
Select the codec to be used for analog lines. North American users should
choose PCMU. All other countries, unless already known, should be assumed
to be PCMA. The default setting is PCMU.
Note:
This option requires system reboot to take effect.
Boost Ringer
Configure whether normal ringing voltage (40V) or maximum ringing voltage
(89V) for analog phones attached to the FXS port is required. The default
setting is "Normal".
Fast Ringer
Configure to increase the ringing speed to 25HZ. This option can be used with
"Low Power" option. The default setting is "Normal".
Low Power
Configure the peak voltage up to 50V during "Fast Ringer" operation. This
option is used with "Fast Ringer". The default setting is "Normal".
Ring Detect
If set to "Full Wave", false ring detection will be prevented for lines where Caller
ID is sent before the first ring and proceeded by a polarity reversal, as in UK.
The default setting is "Standard".
FXS MWI Mode
Configure the type of Message Waiting Indicator on FXS lines. The default
setting is "FSK".
•
FSK
: Frequency Shift Key Indicator
•
NEON
: Light Neon Bulb Indicator.
FXO Frequency
Tolerance
Allows users to adjust the tolerance of the FXO ringing frequency. 63Hz is
considered the standard value and is selected by default.
Summary of Contents for UCM6200 Series
Page 1: ...Grandstream Networks Inc UCM6200 Series IP PBX User Manual...
Page 239: ...P a g e 238 UCM6200 Series User Manual Version 1 0 20 38 Figure 144 Conference Report on CSV...
Page 271: ...P a g e 270 UCM6200 Series User Manual Version 1 0 20 38 Figure 171 Sync LDAP Server option...
Page 313: ...P a g e 312 UCM6200 Series User Manual Version 1 0 20 38 Figure 213 Presence Status CDR...
Page 322: ...P a g e 321 UCM6200 Series User Manual Version 1 0 20 38 Figure 219 911 Emergency Sample...
Page 455: ...P a g e 454 UCM6200 Series User Manual Version 1 0 20 38 Figure 339 Cleaner...
Page 468: ...P a g e 467 UCM6200 Series User Manual Version 1 0 20 38 Figure 351 Network Status...