308925
92
Low Pressure Sensor (Optional)
1.
Follow the
Pressure Relief Procedure
on page 21.
2.
Close the reservoir ball valve (56). See Fig. 112.
3.
Disconnect the low pressure sensor assembly
connector from its mating connector.
4.
Place a container or rag under the filter (54) to
catch any remaining material. Unscrew the low
pressure sensor (PS) from the filter. A small
amount of fluid may drain from the port.
5.
Apply thread sealant and screw the new low
pressure sensor into the filter.
6.
Connect the sensor to the correctly labeled mating
connector.
Fig. 112
8350A
56
54
PS