308925
40
Setup Functions
Solvent Key 2, Level 5
Save Recipes
Default Setting:
1, 2, 3, or 4 (1:1, 2:1, 3:1, or 4:1 ratio
with temperature sensors off), or 5, 6, 7, or 8 (1:1, 2:1,
3:1, or 4:1 ratio with temperature sensors on, feed
pumps on, and high level sensors selected)
Purpose
To save the current setup selections as a new recipe
under a selected number.
A
recipe
is a group of settings that you save for use
with particular materials. A recipe can then be selected
whenever the related material is used.
Recipes 1, 2, 3, and 4 contain the default settings for
1:1, 2:1, 3:1, and 4:1 ratios respectively, with tempera-
ture sensors off. Recipes 1, 2, 3, and 4 cannot be
changed or deleted.
Recipes 5, 6, 7, and 8 contain the default settings for
1:1, 2:1, 3:1, and 4:1 ratios respectively, with tempera-
ture sensors on, feed pumps on, and high level sen-
sors selected. Recipes 5, 6, 7, and 8 cannot be
changed or deleted.
Copy the form on page 58 and use it to record your
recipe settings. Keep your records where they are
accessible to the person doing setup and where they
will not be damaged.
Access
In setup level 5, press key 2 on the keypad to access
the Save Recipe function.
Keypad Display
The key 2 light is green and 5 appears in the keypad
setup level position. See Fig. 46.
System Schematic Panel
There is no related panel display.
Changing Values
Press an arrow key until the number you want to
assign the recipe displays. Only unused recipe num-
bers will be displayed. Exit setup mode from this
function to save the recipe under the selected number
and to run the new recipe.
NOTE:
Recipes 1 through 8 cannot be changed or
deleted.
Fig. 46
2
Solvent Key 2, Level 6
Key is currently inactive.
Solvent Key 2, Level 7
Current Software Revision
Purpose
To display the current software revision of the con-
trol.
Fig. 47
2
Summary of Contents for SuperCat 232721
Page 23: ...308925 23 Notes...
Page 111: ...308925 111 Notes...
Page 112: ...308925 112 Dimensions 8787A 42 in 1067 mm 66 in 1676 mm 74 in 1880 mm...