308925
29
Manual or Spray Mode
Cycle Counting and Material Usage
Cycle counts of the proportioner pump A and B sides
and solvent pump allow the control to keep track of:
Amount of material A and B that the proportioner
has pumped to the gun(s) and/or recirculated to the
reservoirs since the counter was reset
Solvent used since counter was reset
Total Premier pump cycles (non-resettable)*
Total solvent pump cycles (non-resettable)*
Work life time
Runaway pump condition
*
Total cycles can only be viewed in Setup Mode.
Some of the information is used by the control to
activate set system responses, which include:
To run the solvent pump for a set number of cycles
when solvent pump key is pressed
To turn on the feed pumps after a set number of
Premier cycles
Work life time alarm
Runaway pump alarm
Solvent Usage
When key 2 is pressed to display the amount of sol-
vent used, the key 2 light turns green, and the sche-
matic solvent pump light blinks. See Fig. 25 and 26.
The display will show the amount of solvent used since
the value was last reset.
NOTE:
The keypad display of solvent usage is based on
the cycle counts per gallon/liter that were entered
during setup.
There is no alarm associated with this function.
Solvent Usage Reset
To reset the solvent usage totalizer to zero, press key
2 for five seconds.
Fig. 25
2
A
A
B
A
B
A/B
S
B
A B
A/B
S
A
B
A
B
Solvent Pump Usage
Fig. 26
Summary of Contents for SuperCat 232721
Page 23: ...308925 23 Notes...
Page 111: ...308925 111 Notes...
Page 112: ...308925 112 Dimensions 8787A 42 in 1067 mm 66 in 1676 mm 74 in 1880 mm...