308925
16
Installation
4.
Optional: Install the feed pumps and
the 240689 Feed Pump Control Kit.
NOTE:
The 240689 Feed Pump Control Kit is
factory installed on heated proportioners 232713
through 232724. The kit includes necessary parts
to install two air regulators and dolenoids to control
the feed pumps. Refer to manual 308959 for
installation instructions.
It is recommended that the feed pumps have twice
the flow rate of the Premier production flow rate (2
GPM, 7.6 liters/min. maximum). Undersized feed
pumps can cause an alarm or cause the reservoirs
to run dry.
NOTE:
Additional sensors can be purchased to
allow the control to monitor both the full and low
fluid levels.
5.
Optional: Install the 240690 Level Sen-
sor Kit
The optional 240690 Level Sensor Kit includes two
level sensors, to add to the two supplied with the
proportioner. The installation of both low and full
level sensors, along with the change of the level
sensor option in setup, allows the system to be
used with manual or automatic feed with feed
pumps, without changing the sensor locations.
Refer to manual 308860 for installation instruc-
tions.
6.
Optional: Install 240688 Low Pressure
Sensor Kit
This optional kit includes two low pressure sen-
sors, which attach to the reservoir outlet filters
(54). The low pressure sensors, along with a
change in setup, enable the system to detect a
plugged filter and sound an alarm.
Refer to manual 308861 for installation instruc-
tions.