Troubleshooting
Feed Pumps
Problem
Operating Condition
Cause/Solution
Feed pump does not run
In spray or manual mode, schematic
feed pump light is on
Check air regulator setting. Adjust
setting as needed.
Check feed pump setup. See below.
Check air solenoids. See page 72.
If in spray mode, check material
usage display. See page 73.
Replace circuit board. See
Service
on page 87.
In manual mode, feed pump key
pressed, schematic feed pump lights
off
Check feed pump setup. See below.
Check the electrical continuity for the
feed pump key signals and lights.
See page 74.
Replace keypad. See
Service
on
page 87.
Replace circuit board. See
Service
on page 87.
Full level sensor alarm
In spray mode
Check feed pump setup. See below.
Check feed pumps. See “trouble-
shooting” in the feed pump manual.
Install larger feed pumps.
Low level sensor alarm
In spray mode
Check feed pump setup. See below.
Check feed pumps. See “trouble-
shooting” in the feed pump manual.
Install larger feed pumps.
Feed pump will not stop
Schematic feed pump light off
Check feed pump air solenoid. See
page 72.
Feed Pump Setup Check
1.
Make sure one of the level sensor options “with
feed pump” is selected. See
Setup
on page 51.
2.
The Premier pump should go through 1 full cycle
(2 top changeovers) before the feed pumps start.
3.
Make sure the Feed Pump Time setting is set high
enough to fill the reservoirs before an alarm oc-
curs. See
Setup
on page 49.
4.
If both full and low level sensors are installed,
make sure the Feed Pump Time setting (
Setup
on
page 49) is set so the alarm for the full level sen-
sor will occur before the low level sensor alarm.
Base the settings on the Premier pump and the
feed pump capacity.