Setup Mode
Entering Setup Mode
1.
Make sure you are in Manual Mode (Mode Key 0
light is off).
2.
Touch the key (EE) to the setup contacts (TT). See
Fig. 37.
3.
Level 1 appears when Setup Mode is initially
accessed and the Key 2 light turns on. See Fig.
38.
Navigating Within Setup Mode
To go to the next setup level, press key 7.
When key 7 is pressed to change setup levels, the
control will enter the next level while remaining at
the previously active function key.
For example:
If you are in setup level 2 and press
key 4, then press key 7 to change to setup level 3,
you will enter level 3 with key 4 being the active
function.
Arrow keys (
) are used to change setup values
or toggle between values where applicable.
Mode Key (0) is inactive while in Setup Mode.
Saving Changes – Exiting Setup Mode
Any number of functions can be accessed and
changed before taking action to save the changes.
To save all changes and exit Setup Mode:
Touch the key (EE) to the setup contacts (TT). See
Fig. 37. The control will retain the new values and
return to Manual Mode.
Fig. 37
EE
TT
Fig. 38