Pre-Heaters
Operation
The operation of the pre heaters is completely automatic within the PLC
program to maintain the operator set point.
Pre Polymer
The Gusmer HyBrid style heater is constructed from aluminum with a low
watt density that will give very stable temperature control during static
and operating conditions.
Heater Rod
Each pre-heater contains 6 heating elements rated @ 1500 watts each.
Curative
The curative heater is constructed from stainless steel to prevent possible
chemical reaction.
Heater Rod
The pre-heater contains 6 heating elements rated @ 1500 watts each.
Start-Up
Determine that the pre-heaters are filled with chemical and pressurized
before turning on the power.
Over Temp SW
The safety switch is factory set at 220
°
F and cannot be adjusted in the
field.
CAUTION
The over temperature switch on the Heater resets automatically when the
temperature drops below 200 deg F.
Maintenance
There is no normal operating maintenance.
Thermocouple
Over Temp
Safety Switch
Heater Element
Pre Polymer
(2)
Curative
Summary of Contents for BetaCell 241D
Page 6: ...6...
Page 8: ...Specifications System Dimensions 54 108 98 3 16...
Page 11: ...11 DESCRIPTION OF CONTROLS 1...
Page 15: ...15 Help Screen A Help Screen is available for each of the Menu Screens...
Page 24: ...24 Maintenance Menu Press to access the Maintenance screen Password Required...
Page 30: ...30 AutoStart Set Up Screen This screen is for qualified technicians only...
Page 31: ...31 Sleep Mode Set Up Screen This screen is for qualified technicians only...
Page 37: ...37 DESCRIPTION OF MAJOR COMPONENTS 2...
Page 38: ...38 System Schematic...
Page 44: ...44 Buffer tank 2 1 6 7 5 8 9 4 3...
Page 45: ...45 13 10 12 Fumes piped away by others in accordance with plant specifications 11...
Page 55: ...55 AutoFill Valve Maintenance There is no normal operating maintenance Position Indicator...
Page 65: ...65 Hydraulic Power Pack Schematic...
Page 78: ...78 DAILY PROCEDURES 4...
Page 80: ...80 FAULT MANAGEMENT 5...
Page 88: ...88 MAINTENANCE 6...