Pneumatic System
The importance of the Dry Air supply cannot be overstressed as it
provides a moisture-free medium to charge the operating tanks. To
prevent contamination of the air system by a reaction of the Pre-
Polymer fumes with the Curative fumes, the systems are isolated by
means of separate check valves. The recommended air pressure
required to charge the buffer tanks is 60 psi.
NOTE
The minimum recommended air pressure required to maintain the
recirculation valve in a closed position is 100 psi.
Buffer tank Pressurization Valves
Maintenance
There is no normal operating maintenance.
Main Air
Valve
Water Separator
Desiccant Dryer