Metering Unit
Electric 63.3 FLA amps@ 3 x 460 volts; 60 Hz
A-motor 5 hp vector
B-motor 1 hp servo
Max pressure 1500 psi
Max oper pres 1200 psi
Max output 15 lbs/min (110 cc/sec)
Hydraulic Power Pack
Motor 5
hp
Flow rate 6 cc/rev (3 gpm)
Max pressure 3000 psi
Max oper pres 2800 psi
Max temp 160ºF
Reservoir 8
gal
Accumulator 85 cu in
Min cycle time 3 sec
Buffer tanks
Construction
•
Pre Poly: steel ASME certified
•
Curative: stainless steel, ASME certified
Chemical Capacity
•
Pre-Polymer – 20 gallons useable
•
Curative – 10 gallons useable
Oil Jacket
•
Pre Poly-15 gallons
•
Curative – 7.5 gallons
Mixer
•
29 RPM
Max Pressure
•
100 psi
Max temperature
•
180
°
F
Summary of Contents for BetaCell 241D
Page 6: ...6...
Page 8: ...Specifications System Dimensions 54 108 98 3 16...
Page 11: ...11 DESCRIPTION OF CONTROLS 1...
Page 15: ...15 Help Screen A Help Screen is available for each of the Menu Screens...
Page 24: ...24 Maintenance Menu Press to access the Maintenance screen Password Required...
Page 30: ...30 AutoStart Set Up Screen This screen is for qualified technicians only...
Page 31: ...31 Sleep Mode Set Up Screen This screen is for qualified technicians only...
Page 37: ...37 DESCRIPTION OF MAJOR COMPONENTS 2...
Page 38: ...38 System Schematic...
Page 44: ...44 Buffer tank 2 1 6 7 5 8 9 4 3...
Page 45: ...45 13 10 12 Fumes piped away by others in accordance with plant specifications 11...
Page 55: ...55 AutoFill Valve Maintenance There is no normal operating maintenance Position Indicator...
Page 65: ...65 Hydraulic Power Pack Schematic...
Page 78: ...78 DAILY PROCEDURES 4...
Page 80: ...80 FAULT MANAGEMENT 5...
Page 88: ...88 MAINTENANCE 6...