70
Unloading Valve
NOTE:
Different valve shown for
clarity. Orientation of the adjustment
screws is the same.
Pressure Adjustment
The pressure limits can be field adjusted as follows
•
Determine that the accumulator is pre-charged to 1920 psi and that
the manual unloading valve is CLOSED.
•
Turn on the hydraulic motor and allow the pressure to stabilize.
•
Adjust the overpressure (‘O”) limit clockwise to raise the pressure.
•
Slowly crack the manual unloading valve and note the falling
pressure until the under-pressure limit is reached and the pressure
begins to rise. Make small adjustments to the under pressure (“U”)
limit and repeat the bleed process to check the new pressure setting.
“U” under
pressure
“O” over
pressure
Summary of Contents for BetaCell 241D
Page 6: ...6...
Page 8: ...Specifications System Dimensions 54 108 98 3 16...
Page 11: ...11 DESCRIPTION OF CONTROLS 1...
Page 15: ...15 Help Screen A Help Screen is available for each of the Menu Screens...
Page 24: ...24 Maintenance Menu Press to access the Maintenance screen Password Required...
Page 30: ...30 AutoStart Set Up Screen This screen is for qualified technicians only...
Page 31: ...31 Sleep Mode Set Up Screen This screen is for qualified technicians only...
Page 37: ...37 DESCRIPTION OF MAJOR COMPONENTS 2...
Page 38: ...38 System Schematic...
Page 44: ...44 Buffer tank 2 1 6 7 5 8 9 4 3...
Page 45: ...45 13 10 12 Fumes piped away by others in accordance with plant specifications 11...
Page 55: ...55 AutoFill Valve Maintenance There is no normal operating maintenance Position Indicator...
Page 65: ...65 Hydraulic Power Pack Schematic...
Page 78: ...78 DAILY PROCEDURES 4...
Page 80: ...80 FAULT MANAGEMENT 5...
Page 88: ...88 MAINTENANCE 6...