95
114.Open Pre Poly Buffer tank outlet valve
115.Close air ball valve on top of Pre Poly Buffer tank
116.Open inlet air ball valve
117.Access Machine Control screen via Main Menu on PV
118.Touch Auto Shutdown
119.Wait 1 minutes, and Touch Auto Startup
120.Access Status screen via Main Menu on PV
121.System is ready when correct ratio is displayed, temperatures
have reached process temperatures and a green GO is at the
bottom of screen
122.Access Operator screen via Main Menu on PV
123.Select correct Sequence and touch Reset
124.Trigger Gun
NOTE: After Orifice has been in for several minutes shut system
down and re-torque the Orifice due to thermal expansion
1. Verify Pre Poly and Curative Motors are off
Close Remote
Coupling Block
2. Turn valves CW to close Remote Coupling Block
1 min
125.Access Machine Control screen via Main Menu on PV
126.Touch Curative Stop Motor
127.Close and Lock out Curative Buffer tank outlet valve and ball
valve
128.Open Curative Filter Drain ball valve and allow curative to
empty into a waste container
129.Open lid of filter assembly and remove bag filter and dispose
of accordingly
Change Inlet
Curative Filter
130.Replace with new and verify proper fit in housing
10 min
Summary of Contents for BetaCell 241D
Page 6: ...6...
Page 8: ...Specifications System Dimensions 54 108 98 3 16...
Page 11: ...11 DESCRIPTION OF CONTROLS 1...
Page 15: ...15 Help Screen A Help Screen is available for each of the Menu Screens...
Page 24: ...24 Maintenance Menu Press to access the Maintenance screen Password Required...
Page 30: ...30 AutoStart Set Up Screen This screen is for qualified technicians only...
Page 31: ...31 Sleep Mode Set Up Screen This screen is for qualified technicians only...
Page 37: ...37 DESCRIPTION OF MAJOR COMPONENTS 2...
Page 38: ...38 System Schematic...
Page 44: ...44 Buffer tank 2 1 6 7 5 8 9 4 3...
Page 45: ...45 13 10 12 Fumes piped away by others in accordance with plant specifications 11...
Page 55: ...55 AutoFill Valve Maintenance There is no normal operating maintenance Position Indicator...
Page 65: ...65 Hydraulic Power Pack Schematic...
Page 78: ...78 DAILY PROCEDURES 4...
Page 80: ...80 FAULT MANAGEMENT 5...
Page 88: ...88 MAINTENANCE 6...