CAUTION:
•
Avoid injury. Worn pump components can have sharp edges. Wear appropriate gloves
while handling these parts.
6.2.2 Wet end disassembly instructions
Follow these precautions before disassembly:
•
Remove the v-belt or coupling guard.
•
For pumps that are coupled to the motor, uninstall the coupling.
•
On a pump that is v-belt driven, the overhead mount or side-by-side slide base must be adjusted to
loosen the belts.
•
De-energize, lock-out, and tag-out the motor.
•
Check to ensure that the pedestal frame is securely fastened to the foundation, base plate, or work
surface, such as a workbench.
6.2.3 Tools required
In order to disassemble the pump, you need these tools:
•
Allen wrenches
•
Metric stud drivers
•
Cleaning agents and solvents
•
Chisel
•
Dial indicators
•
Hoist and strap
•
Pry bars
•
Sockets
•
Soft face hammer
•
Spanner wrench
•
Torque wrench
•
Wrenches
•
Lifting eyebolt (dependent on pump / motor size)
6.2.4 Disassembly for Metal-Lined
The disassembly steps for Metal-lined and Rubber-lined differ. This section, beginning with
Typical disas-
sembly
and ending with
Remove the shaft sleeve
, pertains to Metal-lined pumps.
For Rubber-lined pumps, refer to the sub-section,
6.2.8 Disassembly for Rubber-Lined on page 94
.
6.2.5 Typical disassembly - Metal-Lined
The XHD slurry pump is available in two models: the basic version, referred to as XHD and the XHD Val-
ue Option. The method of disassembly and assembly can vary between these models. The XHD is a
front pull out design. Typical disassembly steps can be followed for both the XHD and XHD Value Option.
The suction half casing and attached components can be removed for further disassembly and replace-
ment of the suction side liner (562) and adjustable seal ring (822, XHD only) as necessary. After remov-
ing the impeller (101) by disengaging the knock-off ring (149), the gland half casing (100D) can remain
mounted to the pedestal (131) and the casing volute liner (561) removed for replacement. Other compo-
nents such as the gland, packing, seal cover etc. can also be removed in a methodical fashion as need-
ed for inspection and replacement. In addition to traditional sequential disassembly methods, the entire
6.2 Disassembly
XHD Installation, Operation, and Maintenance Manual
83