6.2.22 Locate and lift the volute liner for optional discharge locations (field
replacement) - Rubber-Lined
1.
The Volute Liner (600T) can be installed into the Gland Casing (100D) the field in any of the option-
al discharge orientations.
2.
Remove the Suction casing and Suction Liner assembly as described in the section 'Remove the
Suction Side.
600A
600D
100D
600R
100A
600N
415B
600C
415B
553
Figure 87: Volute liner and impeller lifting
3.
Remove the Impeller as shown in the impeller removal section.
122
600T
101
Figure 88: Impeller Removal
6.2.23 Remove the shaft sleeve
1.
Remove the shaft sleeve (126) from the shaft (122). Use a short pry bar to gently facilitate removal,
if necessary.
2.
Remove the impeller hub o-ring (412A) and shaft sleeve o-ring (412F).