Stuffing box cover
The stuffing box cover used with the dynamic seal option is equipped with two lantern ring connections:
•
One expeller flush connection
•
One expeller drain connection
The lantern ring connection can be used to inject flush liquid or grease when required on specific appli-
cations.
Drain tap
The drain tap allows you to drain the liquid that remains in the expeller chamber upon pump shutdown.
Consider removing this liquid before you service the pump in order to prevent it from hardening, or pro-
tect the pump during freezing weather. The flush tap allows injection of water or steam directly into the
repeller chamber near the base of the repeller vanes.
Injected liquid
Injected liquid can be used in conjunction with the drain in order to flush the chamber of solids or poten-
tially harmful liquids.
6.2 Disassembly
6.2.1 Disassembly precautions
WARNING:
•
Failure to disconnect and lock out driver power may result in serious physical injury or
death. Always disconnect and lock out power to the driver before performing any installa-
tion or maintenance tasks.
•
Electrical connections must be made by certified electricians in compliance with all
international, national, state, and local rules.
•
Refer to driver/coupling/gear manufacturer's installation and operation manuals
(IOM) for specific instructions and recommendations.
•
Risk of serious personal injury. Applying heat to impellers, propellers, or their retaining
devices can cause trapped liquid to rapidly expand and result in a violent explosion. This
manual clearly identifies accepted methods for disassembling units. These methods must
be adhered to. Never apply heat to aid in their removal unless explicitly stated in this
manual.
•
Handling heavy equipment poses a crush hazard. Use caution during handling and wear
appropriate Personal Protective Equipment (PPE, such as steel-toed shoes, gloves, etc.)
at all times.
•
Precautions must be taken to prevent physical injury. The pump may handle hazardous
and/or toxic fluids. Proper personal protective equipment should be worn. Pumpage must
be handled and disposed of in conformance with applicable environmental regulations.
•
Risk of serious physical injury or death from rapid depressurization. Ensure pump is iso-
lated from system and pressure is relieved before disassembling pump, removing plugs,
opening vent or drain valves, or disconnecting piping.
•
Risk of serious personal injury from exposure to hazardous or toxic liquids. A small
amount of liquid will be present in certain areas like the seal chamber upon disassembly.
6.2 Disassembly
82