Guideline
Explanation/comment
If the pump location is overhead, undertake special
precautions to reduce possible noise transmission.
Consider a consultation with a noise specialist.
4.1.2 Foundation requirements
Requirements
•
All equipment being installed must be properly grounded to prevent unexpected static
electric discharge. If not, a static electric discharge may occur when the pump is drained and disas-
sembled for maintenance purposes.
•
The location and size of the foundation bolt holes must match those shown on the assembly draw-
ing provided with the pump data package.
•
The foundation must weigh between two and three times the weight of the complete pump, base-
plate, and drive assembly.
•
Provide a flat, substantial concrete foundation in order to prevent strain and distortion when you
tighten the foundation bolts.
Sleeve-type bolts
1
2
3
4
5
6
Item Description
1.
Baseplate
2.
Shims
3.
Foundation
4.
Sleeve
5.
Dam
6.
Bolt
Figure 11: Sleeve type bolts