![background image](http://html.mh-extra.com/html/goulds-pumps/xhd/xhd_installation-operation-and-maintenance-manual_2247661104.webp)
Figure 82: Removal of expeller
6.2.20 Remove the seal cover and gland half casing assembly
1.
Remove the gland casing and seal cover assembly by supporting the casing assembly with a hoist
hook through the lifting lug.
Figure 83: Removal of seal cover and half gland assembly
2.
Remove the pedestal to casing (427L) and (3701) hardware.
3.
Hoist the casing assembly to the ground so that the seal cover or stuffing box cover can be re-
moved.
388A
354A
184
100D
Figure 84: Seal cover removal
4.
Remove the seal cover retention hex head cap screws (388A) and clipped washers (354A).
5.
Remove the seal cover (184) from the gland half casing (100D). Use a short pry bar to gently and
evenly facilitate disassembly if necessary.
6.2 Disassembly
102
XHD Installation, Operation, and Maintenance Manual