![background image](http://html.mh-extra.com/html/goulds-pumps/xhd/xhd_installation-operation-and-maintenance-manual_2247661132.webp)
600A
600A
600D
600D
100D
100D
553
553
600A
600D
100D
600R
100A
600N
415B
600C
415B
553
Figure 127: Installation of suction half casing with attached components - rubber lined
6.4.6.19 Install packing, lantern ring, and gland
1.
Measure the appropriate length of packing (106) strips by wrapping packing around the shaft sleeve
(126) to estimate the desired length. Carefully cut each strip that is needed ¼” shorter than circum-
ference of the shaft sleeve.
2.
Install packing (106) and lantern ring (105) in the appropriate order that based upon the service di-
lution requirements. See the Maintenance – Packing section for details.
3.
Position the two halves of the gland assembly (107) around the shaft sleeve (126). Assemble the
gland assembly (107) and attach to the stuffing box using the gland adjusting bolts (353).
6.4.6.20 Install the flanges and joint gaskets
1.
Install the two-piece suction and discharge flanges (195C, sizes 150 and above only).
2.
Install the discharge joint flat gasket (351A).
3.
Install the suction joint flat gasket (351B).
NOTICE:
Flange gaskets 351A and 351B are supplied only with metal lined assemblies.
6.4 Reassembly