Figure 53: Removal of suction half casing - metal lined
5.
Remove the hex head casing bolts (600A) from the gland half casing (100D).
6.
Remove the tapered alignment studs (600D) from the gland half casing (100D) using a metric stud
driver.
600A
600A
600D
600D
100D
100D
553
553
Figure 54: Casing bolt removal
6.2.7.3 Remove the remaining suction half components - Metal-Lined
Pump model
Next step to follow
XHD
•
Remove the suction side liner and adjustable seal ring
•
Remove the adjustable seal ring
XHD Value Option
•
Remove the suction liner
6.2.7.4 Remove suction side liner - XHD Value Option - Metal-Lined
1.
Remove the suction side liner retention nuts (357A).
2.
Remove suction side liner (562) from suction half casing (100A).
3.
Remove the suction side liner retentions studs (356E) from the suction side liner (562) using a met-
ric stud driver.
4.
Remove the suction side liner flat gasket (351N).
6.2 Disassembly