![background image](http://html.mh-extra.com/html/goulds-pumps/xhd/xhd_installation-operation-and-maintenance-manual_2247661062.webp)
1
2
3
4
5
6
Item
Description
Item
Description
1.
End plate, drive end
4
3/8-16 nut, 3 required
2.
End plate, pump end
5
3/8 in. washer
3.
Guard half, 2 required
6
3/8-16 x 2 in. hex head bolt, 3 required
Figure 35: Required parts
1.
De-energize the motor, place the motor in a locked-out position, and place a caution tag at the start-
er that indicates the disconnect.
2.
Put the pump-side end plate in place.
If the pump-side end plate is already in place, make any necessary coupling adjustments and then
proceed to the next step.
3.
Put the pump-half of the coupling guard in place:
a) Slightly spread the bottom apart.
b) Place the coupling guard half over the pump-side end plate.
1
2
3
4
Item Description
1.
Annular groove
2.
Pump-side end plate
3.
Driver
4.
Pump half of the coupling guard
5.9 Couple the pump and driver
60