5.17 Shut down the pump
WARNING:
Precautions must be taken to prevent physical injury. The pump may handle hazardous and/or
toxic fluids. Proper personal protective equipment should be worn. Pumpage must be handled
and disposed of in conformance with applicable environmental regulations.
1.
Slowly close the discharge valve.
2.
Shut down and lock out the driver to prevent accidental rotation.
5.18 Deactivate the i-ALERT
®
2 Equipment Health Monitor
NOTICE:
Always deactivate the health monitor when the pump is going to be shut down for an extended
period of time. Failure to do so will result in reduced battery life.
5.19 Reset the i-ALERT
®
2 Health Monitor
To deactivate or reset the i-ALERT
®
2 monitor, please refer to the i-ALERT
®
Always reset the health monitor when the pump is started after maintenance, system change, or being
shut down for an extended period of time. Failure to do so may result in false baseline levels that could
cause the health monitor to alert in error.
1.
Touch a magnet to the health monitor over the ITT logo to turn the power on.
The health monitor begins to establish a new baseline vibration level.
Figure 49: i-ALERT
®
2 Equipment Health monitor
5.17 Shut down the pump
XHD Installation, Operation, and Maintenance Manual
73