![background image](http://html.mh-extra.com/html/goulds-pumps/xhd/xhd_installation-operation-and-maintenance-manual_2247661122.webp)
Pump model
Next step to follow
XHD
•
You will need to assemble the two split stuff-
ing box halves before attaching the stuffing
box to the seal cover. Start with the next step,
Assemble the split stuffing box.
XHD Value Option
•
Go to Install the seal cover instructions.
6.4.6.3 Install the gland half casing and seal cover
1.
Install the tapered alignment studs (375B) into the gland half casing (100D) using a metric stud driv-
er.
375B
100D
388A
354A
184
388A
354A
100D
Figure 111: Gland half casing and seal cover installation
a) Install the seal cover into the casing.
b) With bolts and clipped washers (354A) (388A).
2.
Attach the hoist hook to the gland half casing (100D) lifting lug, such that the casing discharge will
be oriented properly for the application.
3.
Lift the gland half casing (100D) into position and move forward until it is flush with the pedestal
(131) by guiding the tapered alignment studs through the pedestal flanges.
4.
Install the hex nuts (427D) onto the tapered alignment studs (375B).
5.
Install the hex head capscrews (370Y) through the pedestal flange into the gland half casing (100D)
to complete assembly.