manualshive.com logo in svg
background image

EAGLE

Installation, Operation and 

Maintenance Instructions

EAGLE MODEL A100 

ANSI PUMPS

Lubrication information is 

in Section III-A, Item 1b. 

and Section IV-A.

Содержание A100

Страница 1: ...EAGLE Installation Operation and Maintenance Instructions EAGLE MODEL A100 ANSI PUMPS Lubrication information is in Section III A Item 1b and Section IV A...

Страница 2: ...III B Operation Checks 6 III C Shutdown Procedure 6 SECTION IV PREVENTIVE AND CORRECTIVE MAINTENANCE IV A Lubrication 6 IV B Stuffing Box 6 IV C Vibration 6 IV D Alignment Final 6 IV E Performance 6...

Страница 3: ...r protecting the pump during shipment in covered trucks It also provides protection during covered storage at the jobsite and for a short period between installation and start up If the pump is to be...

Страница 4: ...shipped with bedplates Changing the pump casing or bearing frame in the field will require a reshimming of the frame foot The proper number of shims is installed when the pump shaft is level and para...

Страница 5: ...ng connection also refer to packing recommendations 2 Mechanical Seals When mechanical seals are supplied they are installed and adjusted at the factory They must not run dry or in abrasives Connect r...

Страница 6: ...turer Check complete unit for excessive vibration and unusual noises Do not run pump at greatly reduced flow because damage can result III C Shutdown Procedure Back flow through pump will cause revers...

Страница 7: ...e cover off shaft Do not damage oil seal 332A Slide bearing housing off shaft o Straighten tang in lock washer and remove bearing locknut 136 and lock washer 382 Remove ball bearing 112A using a beari...

Страница 8: ...of the stuffing box 2 Remove the impeller and stuffing box 3 Assemble the gland 250 with gaskets and stationary seat and slide the assembly over the shaft 122 or shaft sleeve 126 4 Slide the rotary p...

Страница 9: ...om casing Tighten bolts 370C and jam nuts on bolts 370D e If desired a dial indicator can be used instead of a feeler gauge to check that the bearing housing has been moved the correct distance V D Ad...

Страница 10: ...TERIAL Part Name No Reqd Per Pump Parts List and Materials of Construction 1 1 1 1 Set 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 4 1 1 4 24 3 4 3 4 2 1 2 2 6 1 1 2 3 2 1 1 1 1 Casing Impelle...

Страница 11: ...11 Model A100 S M L Assembly View of 8 Pumps Only 100 239 105 106 412A 469D 101 351 122A 355 353 107 333A 370D 113A 496 361A 168A 123 210 261 126 370H 184 370 228A 112A 134A 332A 136 382 370C 370 503...

Страница 12: ...12 Model A100 M L 132 370 184 168A 360D 496 108 107 355 353 123 113A 228A 370C 134A 136 382 332A 112A 370D 361A 370E 370H 126 122A 210 333A 106 370F 131 239 105 469D 412A 106 101 351 100...

Страница 13: ...13 Model A100 X 101 412A 469D 106 105 184 351 100 370H 239 355 107 370 370E 131 228A 370F 106 333A 469B 353 113A 168A 123 261 126 108 210 132 122A 360D 370D 371C 109A 332A 136 382 496A 134A 112A 496...

Страница 14: ...as required 17 Coupling or pump and driver misaligned check alignment and realign if required 18 Impeller diameter too small consult factory for proper impeller diameter 19 Improper pressure gauge loc...

Страница 15: ...ing instructions VIII A Spare Parts To insure against possible long and costly downtime periods especially on critical services it is advisable to have spare parts on hand 1 For critical services It i...

Страница 16: ...MP COMPRESSOR LTD 7025 5 Street S E Calgary AB T2H 2G2 Canada ANSI Centrifugal Pumps Multistage Horizontal Pumps Vertical Sump Pumps Rotary Screw Compressor Air Gas Dryers www eagle pc com Printed in...