33
NO
NO
NO
YE
S
YE
S
NO
YE
S
service person
out of fuel
Are there pellets in the
container?
Fill the
container with
pellets
Is STB turned on (protection
active)?
Deactivate protection by
pressing button
Does mechanic pressure
control for negative control
in firebox operate?
1. Check pressure control with artificially created negative
pressure
2. Check sealing of doors and hatches on the boiler
3. Check air intake in the boiler room
4. Check flue draught
5. Clogged or dirty firebox
Does the dosing reduction
work?
1. Check option of block screw
2. Check STB
4. Check the feeding screw