11. PRESSURE AND RETURN PIPE
Outputs of the pressure and return pipes on the boiler are 1'' and you cannot reduce them or taper to the
first bifurcation. Use a 1’’ steel pipe or a copper pipe with the outside diameter of Ø28mm or greater.
When installing, strictly observe the slopes of pipes as they need to be at 0.5% (5mm. per meter of pipe)
and the venting system (boiler, pipes, radiators).
Set up a thermo hydrometer at the pressure line to show the water pressure in the system and the water
temperature at the back end of the boiler.
12. BUILT-IN COMPONENT OF THE STOVE
- In the stove, there are the following built-in components:
- Safety valve
- Circulation pump
- Automatic air valve
- Expansion container and
- Charging and discharging tap
For this reason there is no need to install these components again. The stove is complete, which is a great
advantage most all of because there is no need for additional space for the listed components.
Summary of Contents for Aqua ECOLOGIC
Page 32: ...AQUA ECOLOGIC instructions for use maintenance and installation September 2015 32 Figure 12...
Page 41: ...AQUA ECOLOGIC instructions for use maintenance and installation September 2015 41 service...
Page 42: ...AQUA ECOLOGIC instructions for use maintenance and installation September 2015 42 service...
Page 43: ...AQUA ECOLOGIC instructions for use maintenance and installation September 2015 43 service...
Page 44: ...AQUA ECOLOGIC instructions for use maintenance and installation September 2015 44 service...
Page 45: ...AQUA ECOLOGIC instructions for use maintenance and installation September 2015 45 service...
Page 52: ...AQUA ECOLOGIC instructions for use maintenance and installation September 2015 52...