13. INSTALLING AND IGNITING
Before the combustion starts entire system of central heating should be water-filled, well-vented, and the
stove properly connected to the chimney, as discussed in previous counts.
Recommended operating pressure of water is 1 to 1.9 bar. Best to be within the limits of 1.2 to 1.6 bar.
The test pressure can be up to 1.9 bar.
NOTE:
The stove must not be used without water.
It must be tied to the installation to which the consumers
are connected (radiators) with minimum power of 8 kW.
14. PRACTICAL INSTRUCTIONS AND TIPS FOR THE USE OF THE HEATING
SYSTEM
-All connections must be well sealed and fastened. There must be no leakage of water.
-Before you turn the stove on for the first time, the complete installation shall be tested with water at a
maximum pressure of 1.9 bar.
-It is preferred that the water be at least once released out of the system due to the dirt which is located in
the system.
-Make sure that all valves between the stove and the installation are open.
-Make sure that all the air from the boiler and installation is released before placing the boiler in operation.
For this reason, the installation should be filled with water slowly so that the air manages to get out of the
installation.
-During the ignition and cooling phase, the stove can expand and contract, and at the same time you can
hear little crackling. This is absolutely normal, because the structure is made of steel and this certainly can
not be regarded as a disadvantage.
Basic programming that is done in the factory guarantees proper operation and prevents overheating
problems when you first turn on the stove, and for later as well.
15. FILLING WITH WOODEN GRANULES
Refuelling is done on the upper side of the stove by opening the lid. Put the wooden granules in the tank.
Its load capacity when it is empty is about three 15 kg bags, a total of 45kg of pellets.
To simplify the procedure, do this in two stages:
-Put half a bag into the tank and wait until the pellets reach the bottom. Turn the stove on.
-When the stove starts to work normally put the pellets as needed in the storage for pellets.
-Do not ever remove the security grid from the tank. When putting the wooden granules in, prevent the bag
from coming into contact with hot surfaces.
Summary of Contents for Aqua ECOLOGIC
Page 32: ...AQUA ECOLOGIC instructions for use maintenance and installation September 2015 32 Figure 12...
Page 41: ...AQUA ECOLOGIC instructions for use maintenance and installation September 2015 41 service...
Page 42: ...AQUA ECOLOGIC instructions for use maintenance and installation September 2015 42 service...
Page 43: ...AQUA ECOLOGIC instructions for use maintenance and installation September 2015 43 service...
Page 44: ...AQUA ECOLOGIC instructions for use maintenance and installation September 2015 44 service...
Page 45: ...AQUA ECOLOGIC instructions for use maintenance and installation September 2015 45 service...
Page 52: ...AQUA ECOLOGIC instructions for use maintenance and installation September 2015 52...