ECOLOGIC 30 | instructions for use, maintenance and installation |
June 2015
60
Displayed information is:
tH2O
temperature of heating water in the boiler
rH2O
temperature of heating water on return
tFLU
temperature of smoke gases ((H2O )+30-90°C),
tChb
temperature of fire in combustion chamber (615°C+-40°C)
floU
inlet of air-oxygen into combustion device (480°C +- 40°C)
FanI
voltage on fan 1 (130V +- 15V)
FedI
percentage of pellet dosing into the burner (70% +- 20%)
Once you have completed viewing information, use + and - buttons to find information "tH2O". When
finding it, short press ON/OFF button to return to previous state.
If the display indicates "alarm", cause of the alarm must be determined with alarm list (see page 31).