The stove is on the plastic pins that have M10 bolts (4 items), that are threaded into the stove base. At the
screws there are M10mm threaded nuts to the plastic parts. The legs are wound up all the way to the base
of the stove. After unpacking the stove, when you put it in a place where it will be located, it is necessary
to unscrew all the legs, so that a total height from the floor to the base of the stove is about 25mm. When
you are done with nivelation of the stove that needs to stand horizontally, tighten the nuts with a 17 wrench,
which needs to approach the base of the furnace, and at the same time hand-holding the plastic part of the
legs, tighten the nut. The height of about 25mm from the floor to the base is needed for better circulation of
air and cooling the stove. In this way you protect the stove from overheating and you extend its life.
If the surrounding walls and/or floors are made of materials that are
not resistant to heat,
then one should
use adequate protection using the insulating material that does not burn.
Always make sure that you leave a safe distance (about 35/40 cm) between the stove and furniture, home
appliances, etc. To protect the floor if it is made of combustible materials, we suggest you put a metal plate
under the stove on the floor with the thickness of 3-4 mm that will stretch 30 cm in front of the stove.
The stove must be at least 25 cm away from the surrounding walls.
Always leave at least 15 cm
between the rear side of the stove and the wall to allow for proper air circulation, or for the air to flow properly
in that area.
If the stove is installed in a kitchen with a trellis for drawing out air or if it is placed in the room with appliances
that use solid fuel (such as a wood burning stove), always make sure that the amount of inlet air in the room
is sufficient to ensure safe operation of the stove.
If a smoke channel goes through the ceiling, it should be properly thermally insulated using the protection
out of insulating materials that does not burn. When the stove is set up into place, it should be levelled
using pins.
DANGER !
The exhaust gas Armour
must not be
connected to:
- the smoke pipe used by another heat generator (boilers, furnaces, fireplaces, stoves, etc.),
- the air drawing system (grilles, ventilation openings, etc), even if the system is inserted into the drain pipe.
Summary of Contents for Aqua ECOLOGIC
Page 32: ...AQUA ECOLOGIC instructions for use maintenance and installation September 2015 32 Figure 12...
Page 41: ...AQUA ECOLOGIC instructions for use maintenance and installation September 2015 41 service...
Page 42: ...AQUA ECOLOGIC instructions for use maintenance and installation September 2015 42 service...
Page 43: ...AQUA ECOLOGIC instructions for use maintenance and installation September 2015 43 service...
Page 44: ...AQUA ECOLOGIC instructions for use maintenance and installation September 2015 44 service...
Page 45: ...AQUA ECOLOGIC instructions for use maintenance and installation September 2015 45 service...
Page 52: ...AQUA ECOLOGIC instructions for use maintenance and installation September 2015 52...