ECOLOGIC 30 | instructions for use, maintenance and installation |
June 2015
14
Power supply cable must never reach 80 °C above ambient temperature.
If you want to
connect the boiler directly to electrical network, you must install a bipolar switch with
minimum distance of 3 mm between contacts, suitable for required electrical voltage and in
accordance with regulations in force. Bipolar switch must always be accessible, even after the
boiler is installed.
Electrical connection
The pellet boiler must be connected to electrical network. Power supply cable is 3 m long, white and
designated with "220 V". Other connection cable is intended for connection of pump, is black and
designated with "Pump".
Figure 8
White – Boiler supply (220 V)
Black – Pump
If the power supply cable is damaged, it must be replaced. It can only be replaced by an authorized
person.
Electrical connection must be easily accessible even after the pellet boiler is installed.
ATTENTION
When the boiler installation is finished, it is mandatory to perform measurements of smoke
gases discharge.
white cable
boiler supply
black cable
pump
Summary of Contents for Aqua ECOLOGIC
Page 32: ...AQUA ECOLOGIC instructions for use maintenance and installation September 2015 32 Figure 12...
Page 41: ...AQUA ECOLOGIC instructions for use maintenance and installation September 2015 41 service...
Page 42: ...AQUA ECOLOGIC instructions for use maintenance and installation September 2015 42 service...
Page 43: ...AQUA ECOLOGIC instructions for use maintenance and installation September 2015 43 service...
Page 44: ...AQUA ECOLOGIC instructions for use maintenance and installation September 2015 44 service...
Page 45: ...AQUA ECOLOGIC instructions for use maintenance and installation September 2015 45 service...
Page 52: ...AQUA ECOLOGIC instructions for use maintenance and installation September 2015 52...