Configuring Setup Menu and System Configuration Menu Parameters
Start-up and Configuration
Bundle 6X.7.21
To configure bundle 6X.7.21, proceed as follows:
To enable the Contact Card Reader, press
1
to:
• set “HCR2”, for Sankyo card reader.
If “PANASONIC” is selected, then change the option to HCR2. Otherwise the card reader
will fail showing a red-X card reader error.
• set “Omron” (not used in North America).
• set “None” (if no card reader).
To enable the Printer Port, press
2
to:
• set “USB”, for using Ethernet between the POS and dispenser for communication.
• set “COM3”, for using two-wire between the POS and dispenser for communication.
To enable the Contactless Card Reader, press
3
to:
• set “OTI”, for using GCM for Contactless.
• set “None”, if no GCM is installed.
To select the Mode, press
4
to:
• set “SPOT”, for using Ethernet between the POS and dispenser for communication.
• set “Diagnostics”, the SPOT Check or SPOT Dash Tool.
• set “CRIND BIOS”, for using two-wire between the POS and dispenser for
communication if you want to use the CRIND diagnostic card.
Figure 3-13: System Config Menu for Bundle 6X.7.21
9
Press
OK
to save changes and exit.
10
Press
CANCEL