Revolving door TSA 325 NT
9
Installation
4.2.2 Aligning the floor ring
à
In order to ensure trouble-free functioning of the revolving door TSA 325 NT, the floor ring must be aligned
perfectly level (±1 mm).
Top edge of finished floor level = Top edge of floor ring
X
Align the floor ring every 30–40 cm using a levelling device and underlay it.
X
Align the drive box as well for underfloor installation, see section 5.6 Revolving door in all-glass version (TSA
X
Aligning the centre of the floor ring:
The centre of the floor ring has to have the same height as the outer floor ring
(height of centre = height of outer edge)
Mounting the revolving door TSA 325 NT without the floor ring is also possible optionally if the finished floor
level has a sufficient load-bearing capacity.
à
The installed floor ring must be protected against loading until the screed is poured.
à
The visible stainless steel surface must be protected with tape!