Revolving door TSA 325 NT
4
Security
1.2 Safety instructions
à
The mandatory installation, maintenance and repair work must be performed by properly trained personnel
authorised by GEZE.
à
The country-specific laws and regulations are to be observed during safety-related tests.
à
GEZE is not liable for any injuries or damage whatsoever resulting from unauthorised changes to the system.
à
GEZE does not accept any warranty for combinations with third-party products.
à
Furthermore, only original GEZE parts may be used for repair and maintenance work.
à
Connection to the mains voltage must be carried out by a qualified electrician. The mains connection and
equipment ground conductor test must be performed in accordance with VDE 0100 Part 610.
à
Before connecting the onsite power supply circuit, a ground connection must be completed (connect to equi-
potential bonding).
à
Use an on-site automatic cut-out as the line-side disconnecting device with locking option, the dimensioning
of which is matched to the type, cross-section, type of routing and ambient conditions of the on-site feeder.
GEZE recommends separate fuse protection for the door drive.
à
Protect the button program switch (TPS-KDT) against unauthorised access.
à
In compliance with Machinery Directive (2006/42/EC), a risk analysis must be performed and the door system
identified in accordance with CE Marking Directive 93/68/EEC before the door system is commissioned.
à
Observe the latest versions of directives, standards and country-specific regulations, in particular:
à
ASR A1.7 “Doors and gates”
à
EN 16005: 2012 “Power operated pedestrian doorsets – Safety in use– Requirements and test methods”
à
VDE 0100-600 "Installation of low-voltage systems - Part 6 Tests”
à
Accident-prevention regulations, especially DGUV A1 “General regulations” and BGV A2 “Electrical installa-
tions and equipment”
à
DIN EN 60335-2-103 "Household and similar electrical appliances; Particular requirements for drives for
gates, doors and windows"
à
Use lifting tools adapted to the weights of the system parts.
à
Check the weight distribution in the ceiling construction before lifting.
à
Observe the Load Handling Regulation (LasthandhabV).
The following table lists the weights of the individual components depending on their diameter (passage height
here 2500 mm, canopy height 200 mm, without air curtain).
Other equipment options and canopy heights may deviate:
Floor ring
Fixed panel
Ceiling structure
Door leaf
Drive unit
Ceiling panel
Ø 2400
25 kg
70 kg
70 kg
70 kg
80 kg
100 kg
Ø 3000
35 kg
90 kg
90 kg
85 kg
80 kg
140 kg
Ø 3600
50 kg
105 kg
120 kg
100 kg
80 kg
200 kg
This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory
or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction
concerning use of the appliance in a safe way and understand the hazards involved.
à
Children shall not play with the appliance.
à
Cleaning and maintenance shall not be carried out by children without supervision.
à
The door system must be unplugged from the mains connection during maintenance and cleaning work.
à
No persons may pass through the door system during repair or maintenance work.
1.3 Safety conscious working
à
Secure workplace against unauthorised entry.
à
Watch the swivelling range of long system parts.
à
Never carry out work with a high safety risk (e.g. installing the drive, cover or door leaf) while alone.
à
Secure the cover/drive panels against falling.
à
Only use the cables prescribed in the cable plan provided. Cables must be shielded in compliance with the
wiring diagram.
à
Secure loose, internal drive cables with cable ties.
à
Before working on the electrical system:
à
Disconnect the drive from the 230 V mains and check to ensure that it is not supplied with power.
à
disconnect the control unit from the 24-V rechargeable battery.
à
note that if an uninterruptible power supply (UPS) is used, the system will still be supplied with power
despite the fact that the power supply is disconnected.
à
Always use insulated wire-end ferrules for wire cores.