76
Duration to set preset after input off x seconds:
Specify the amount of time the
GV-IP Speed Dome stays in “Input on” preset point before moving to “Input off” preset
point.
Note:
The input settings only function after you start
Input
monitoring manually or by
schedule. To configure the input monitoring, see
5.4 Monitoring
.
For related PTZ settings, see
Chapter 4 PTZ Control Panel
.
5.2.1.2 Output Setting
The GV-IP Speed Dome can connect 1 output device.
Figure 5-5
Select
Enable
to start the output device. Choose the output signal that mostly suits the device
you are using: N/O (Open Circuit), N/C (Grounded Circuit), N/O Toggle, N/C Toggle, N/O
Pulse and N/C Pulse. For
Toggle
output type, the output will remain on once it is triggered
until the next trigger. For
Pulse
output type, the output is triggered for the amount of time you
specify in the Toggle Pulse Mode for x Seconds field.