[Alarm]
Select
Yes
or
No
to enable or disable the alarm function. The default settings for all the
alarms are set to
NO
.
Figure 4-44
•
When
Door Entry/Exit Control
or
Parking Entry/Exit Control
is selected in the
Function Setting
page (Figure 4-41), these options become available:
Option
Description
Held Open
This alarm activates whenever the door is held open over the set
period of time.
Forced Open
This alarm activates whenever the door is opened by force.
Fire Alarm
This alarm activates whenever fire is detected.
Access Denied
This alarm activates whenever entry is denied due to using the
wrong card or entering the wrong password.
Tamper
This alarm activates whenever vandalism occurs, e.g. the opening
of Controller’s cabinet.
•
When
Elevator Control
is selected in the
Function Setting
page (Figure 4-41), these
options become available:
Option
Description
Fire Alarm
Access Denied
Tamper
See the same option above.