GV-AS400 Controller
53
3
3.3.3 Restoring Factory Defaults
You can choose to restore only
Basic Settings
or
All Settings
to factory default values. For
the contents of Basic Setting
,
see
3.4 Web-Based Configurations.
To restore Basic Settings to factory defaults:
Press the
Default
button, between the output 16 and RS-485 connectors, for 3 seconds.
After this it may take up to 3 minutes to restore Basic Settings of GV-AS400 to default
factory values.
Figure 3-14
To restore All Settings to factory defaults:
1. Remove the jumper cap from
JP6
to
JP7
.
2. Press the
Reset
button in the upper center of GV-AS400 circuit board. All input LEDs
should light on.
3. Remove the jumper cap from
JP7
back to
JP6
.
After above steps, it may take up to 3 minutes to restore all settings to factory default values.
If GV-ASKeypad is connected, the message “Memory Test on Keypad” will appear indicating
the default loading is in progress.
Figure 3-15
Summary of Contents for GV-AS Series
Page 10: ......
Page 11: ...1 GV AS100 Controller...
Page 14: ...4 1 1 3 GV AS100 Board Layout Figure 1 3...
Page 32: ...2 GV AS110 Controller...
Page 49: ...3 GV AS400 Controller...
Page 92: ...4 Optional Devices...
Page 150: ...5 GV ASManager Quick Start Guide...
Page 167: ...6 Troubleshooting...