[Interlock]
When the option is enabled, the two mentioned doors will be interlocked,
allowing only one door to be opened at a time.
[Events]
Set the parameters for the events.
•
When
Door Control
is selected in
the
Function Setting
page (Figure 3-20), these
options become available:
Option
Description
Anti-Passback
Enables or disables the Anti-Passback function.
Lock Reset Time
Sets the time (1 to 255 sec.) that a door remains open after which
the door will automatically be locked.
Held Open Time
Sets the time (5 to 9999 sec.) that a door can be held open before
an alarm is generated.
Fire Action
Locks or unlocks the door when a fire condition occurs. Otherwise,
remains the door’s current state by selecting
Unchanged
.
Alarm Continuous
Time
Sets the time (1 to 10 sec.) that the alarm will continuously go off
before it ends.
•
When
Parking Control
is selected in
the
Function Setting
page (Figure 3-20), these
options become available:
Option
Description
Anti-Passback
See the same option above.
Relay On Time
Sets the time (1 to 255 sec.) that a gate remains open after which
the gate will automatically be closed.
Held Open Time
Fire Action
Alarm Continuous
Time
See the same option above.
•
When
Elevator Control
is selected in the
Function Setting
page (Figure 3-20), these
options become available:
Option
Description
Relay on Time
Fire Action
See the same option above.
Alarm Continuous
Time
See the same option above.
Summary of Contents for GV-AS Series
Page 10: ......
Page 11: ...1 GV AS100 Controller...
Page 14: ...4 1 1 3 GV AS100 Board Layout Figure 1 3...
Page 32: ...2 GV AS110 Controller...
Page 49: ...3 GV AS400 Controller...
Page 92: ...4 Optional Devices...
Page 150: ...5 GV ASManager Quick Start Guide...
Page 167: ...6 Troubleshooting...