GV-AS100 Controller
5
1
1.2 Installation
Please open GV-AS100 cabinet and wire the necessary connections to the terminal block as
illustrated below.
Figure 1-4
Pin Function
Pin Function
Pin Function
1
12V Power
9
12V Power Supply
17 Door COM
2 GND
10 GND
18
Door
NC
3
RS-485 A+ for ASBox /
ASNet or PC connection
11
Sensor IN1
19 Door NO
4
RS-485 A-for ASBox /
ASNet or PC connection
12 Button
IN2
5
RS-485 B+ for GV-
Reader connection
13 Fire
IN3
6
RS-485 B- for GV-
Reader connection
14 IN
COM
7
Wiegand Data 0
15
Alarm COM
8
Wiegand Data 1
16
Alarm NO
Summary of Contents for GV-AS Series
Page 10: ......
Page 11: ...1 GV AS100 Controller...
Page 14: ...4 1 1 3 GV AS100 Board Layout Figure 1 3...
Page 32: ...2 GV AS110 Controller...
Page 49: ...3 GV AS400 Controller...
Page 92: ...4 Optional Devices...
Page 150: ...5 GV ASManager Quick Start Guide...
Page 167: ...6 Troubleshooting...