66
Input Type
Input Function
Description
Normal Input
Enable Latch
Disable Latch
The Normal Input is used for a normal
detection mode in which the input is set to
trigger an output. Instead of constant output
alarm in N/O and N/C, the
Enable Latch
option provides a momentary alarm when
triggered.
Door #
Fire Zone
Tamper Zone
Exit Button
Door Contact
Depending on the type of sensor and the
location where it is installed, select the best
Input Function name to fit the sensor
description. When the sensor is activated, an
alarm event may occur and it can also trigger
alarms. For the type of alarm, see [Alarm],
3.4.3.B Parameter Setting
.
For example, when the
Door Contact
sensor
detects unauthorized access, a “Force Open”
type of event occurs and the event may
trigger the “Force Open” alarm.
Gate #
Fire Zone
Tamper Zone
Exit Button
Car Detection
See the “Door #” Input Type above.
For example, when the
Car Detection
sensor
detects any car driving by, a “Park Entry” or
“Park Exit” type of event occurs and the
parking gate will respond the event
accordingly.
Relay #
Fire Zone
Tamper Zone
See the “Door #” Input Type above.
For example, the
Tamper Zone
sensor is
installed on GV-AS400. So whenever there is
any attempt to open the GV-AS400’s cabinet,
the “Tamper” type of event occurs and the
event may trigger the “Tamper” alarm.
Note:
For alarm outputs, the corresponding alarms must be enabled (YES) in the
Parameter Setting
page (Figure 3-21). If alarms are set to be disabled (NO), then the
alarm function here will not work when triggered.
Summary of Contents for GV-AS Series
Page 10: ......
Page 11: ...1 GV AS100 Controller...
Page 14: ...4 1 1 3 GV AS100 Board Layout Figure 1 3...
Page 32: ...2 GV AS110 Controller...
Page 49: ...3 GV AS400 Controller...
Page 92: ...4 Optional Devices...
Page 150: ...5 GV ASManager Quick Start Guide...
Page 167: ...6 Troubleshooting...