MENU
PAR
Description
UM
Type
Def
Min
Max
ACCESS
26.05.06
11040
REV OPEN current thr
A
FLOAT 1
0
1000
R/W
Current threshold for brake opening, REV.
Set this parameter only in control mode V/f or FOC OL.
26.05.07
11042
REV OPEN torque thr
%
FLOAT 0
0
200
R/W
Torque threshold for brake opening, REV.
Set this parameter only in control mode FOC CL.
26.05.08
11044
REV OPEN speed thr
rpm
FLOAT 20
0
1000
R/W
Speed threshold for brake opening, REV.
26.05.09
11048
REV OPEN speed set
rpm
FLOAT 50
0
1000
R/W
Speed threshold for brake opening, REV.
26.05.10
11050
REV CLOSE speed thr
rpm
FLOAT 100 1
1000
R/W
Speed threshold for brake closing, REV.
26.05.11
11052
OPEN pre torque
%
FLOAT 50
0
200
R/W
Torque injected at time of brake opening.
Not active in V/f mode.
26.05.12
11120
CLOSE delay disable
ms
FLOAT 10
0
10000 R/W
Delay for disabling drive after brake closing.
26.05.13
11138
OPEN delay
ms
FLOAT 10
0
10000 R/W
Delay for brake opening.
This time starts when the speed and current thresholds are exceeded.