ADV200-HC Manual
Page 43 of 55
26.17 FIRMWARE
Read-only menu showing the application version and release.
MENU
PAR
Description
UM
Type
Def
Min
Max
ACCESS
26.17.01
12102
Version
*
INT
*
*
*
R
Application version.
4.1 ALARMS
The table shows the alarms for the application, displayable on the keypad.
DISPLAY
DESCRIPTION
OPERATION
PARAMETERS
Parameter setting error
Check parameter settings.
JOYSTICK
Error in commands received from
joystick or button panel.
Check that no multiple commands are entered.
Check wiring and setting of joystick or button panel.
BRAKE
Inequality detected between brake
command and feedback beyond
allowed time.
Check brake feedback wiring or setting of “ALLARM
CONFIG\Brake fbk time” parameter.
OVERLOAD 1
Overload detected
Check load weight or setting of OVERLOAD function
parameters.
OVERLOAD 2
Overload detected
Check load weight or setting of OVERLOAD function
parameters.
IMPACT
Impact detected.
Check if load has struck an obstacle or check setting
of ANTI IMPACT function parameters.
LIMIT SWITCH
Limit switch tripped.
You can move only in the direction opposite that of
the tripped limit switch.
ELS FAULT
ONLY FOR …-ELS-VM DRIVE
Position error threshold between
Virtual Master and commanded shaft
exceeded
Check cause of fault on “slave” drive.
HL FAULT
ONLY FOR ...-HL-M DRIVE
Torque error threshold between master
motor and slave motor exceeded
Check cause of fault on “slave” drive.
SLAVE FAULT
ONLY FOR …-ELS-VM or ...-HL-M
DRIVE
“Slave” drive in alarm or “slave“ drive
has not executed command to
open/close brake or to enable drive.
Check cause of fault on “slave” drive.