ADV200-HC Manual
Page 35 of 55
The digital Enable input must be shown on every drive and takes precedence over the enable command
received from the “Virtual Master”.
The operator must be able to enable the “ELS src” and “ELS Align” commands whenever he wants. Therefore,
On/Off switches will be placed on the control panel to command the relative digital inputs of the drive.
MENU
PAR
Descrizione
UM
Tipo
Def
Min
Max
ACCESSO
26.11.01
11118
Ki gain
*
FLOAT 2000 0
10000 R/W
Integral gain of position regulator
26.11.02
11150
Kp gain
*
FLOAT 0.1
0
10000 R/W
Proportional gain of position regulator
26.11.03
11172
ELS align spd
rpm FLOAT 1000 0
6000
R/W
Speed reference used for realignment.
26.11.04
11216
ELS align pos
m
FLOAT 2
0
1000
R/W
Absolute position reached in case of realignment command.
26.11.05
12028
ELS pos err
m
FLOAT 1
*
*
R
Error between position of hook (trolley or rope) and position reference indicated by Virtual
Master block.
26.11.06
12056
ELS mode
*
ENUM
Not
Follow
*
*
R
0 Not Follow
Drive does NOT follow commands and references sent by master block
1 Follow
Drive follows commands and references sent by master block
26.12 HELPER
Helper (HL) configuration allows a group of drives (maximum of 4) to work with a torque limit on the same
mechanical shaft.
The torque reference is generated by the master drive (-M), which receives movement commands (FWD, REV)
and the speed reference (from digital or analog input) and sends the torque reference to the slave(-S) drives
via the FastLink synchronous communication bus.
This function is allowed only in FLUX VECTOR OL or FLUX VECTOR CL regulation mode.
The following example shows a typical configuration of the digital inputs and outputs of the ..
HL-M
drive with
EXP-IO-D6A4R1-ADV expansion card (optional), EXP
‐
FL
‐
XCAN
‐
ADV card (required) and encoder for
applications that require the use of one or more drives per mechanical shaft.
This configuration lets you connect a joystick/button panel for movement commands, brake/feedback
management, limit switch sensors, enabling of AntiImpact function, alarms reset button, and communication
with the other drives of the mechanical shaft.
Digital input signals are set on the HOIST&CRANE / DIGITAL INPUTS menu.
Digital output signals are set on the HOIST&CRANE / DIGITAL OUTPUTS menu.