ADV200-HC Manual
Page 12 of 55
MENU
PAR
Description
UM
Type
Def
Min
Max
ACCESS
allowed limit (limit switch OFF)
1 = Norm Open = Normally open when position of controlled element does not exceed
allowed limit (limit switch OFF)
2 None =
Limit switches not wired
26.02.09
11144
App Load Default
*
BOOL Off
*
*
R/W
Command for loading default parameters; ONLY parameters for HOIST&CRANE application
will be reloaded.
26.02.10
11146
Define axis length
*
ENUM
Define
length
*
*
R/W
Activation of procedure for defining rope length.
26.02.11
11148
mpr
m/gir FLOAT 0.01
0
1000 R/W
Reduction ratio of motor rpms to movement of mechanical shaft.
This parameter can be entered manually or calculated by the application via the rope length
definition procedure.
This parameter can also be written outside the procedure.
26.02.12
11192
Measure 1
m
FLOAT 0
0
1000 R/W
During the procedure for defining rope length, you are asked to enter the measured length in
this parameter (for details, see “ROPE LENGTH DEFINITION PROCEDURE”).
This parameter can be changed ONLY in this procedure.
26.02.13
11198
Known position
m
FLOAT 0
0
1000 R/W
During the rope length definition procedure, you will be asked to enter a
“
known position
”
in
this parameter, i.e., to position the hook (for a hoist) in a position where you can measure the
distance between the hook and the axis of the rope winder drum and enter the distance in this
parameter.
This parameter can also be written outside the procedure, which will change the specification
of hook position (trolley or beam).
26.02.14
11200
Measure load
m
FLOAT 0
0
1000 R/W
During the procedure for defining rope length, you are asked to enter the distance between the
hoist hook groove and the center of gravity of the load in this parameter.
This parameter can be changed outside this procedure.