TYPICAL CONNECTION DIAGRAM
The Hoist&Crane application for ADV200 drives does not require a higher-level control device such as a PLC.
Therefore, the application can be controlled via discrete digital I/Os (digital input and output terminals of the
ADV200 control card and optional expansion cards) or via the fieldbus configuration channel
(COMMUNICATION menu of drive regardless of the type of fieldbus used).
The following example shows a typical configuration of the digital inputs and outputs of the drive with the
optional EXP-IO-D6A4R1-ADV expansion card and the optional encoder for applications requiring a single
drive for each mechanical shaft.
This configuration lets you connect a joystick/button panel for movement commands, brake/feedback
management, limit switch sensors, enabling of AntiImpact function, and alarm reset button.
Digital input signals must be set on the HOIST&CRANE / DIGITAL INPUTS menu.
Digital output signals must be set on the HOIST&CRANE / DIGITAL OUTPUTS menu.