ADV200-HC Manual
Page 39 of 55
26.14 DIGITAL OUTPUTS
This menu contains the digital output settings.
Two steps are required for changing the digital outputs:
(
The example shows a change in the PAD, which controls the brake via digital output 2.
)
•
Specify in the HOIST&CRANE application the PAD on which to write the command:
Main menu\ HOIST&CRANE \ DIGITAL OUTPUTS\ Brake cmd dest = PADxx.
•
On the ADV menu, link PADxx (i.e., the brake command) to digital output 2:
Main menu\ DIGITAL OUTPUTS\Digital output 2 src = PADxx.
MENU
PAR
Description
UM
Type
Def
Min
Max
ACCESS
26. 14.01 11008
Anti Impact dest
*
ENUM Null
*
*
R/W
Digital output to signal Anti Impact function active.
26. 14.02 11176
Brake cmd dest
*
ENUM Pad 1 *
*
R/W
Digital output to control brake contactor.
26. 14.03 11182
Hoist Spd up dest
*
ENUM Null
*
*
R/W
Digital output to signal Hoist speed up active.
26. 14.04 11184
Power Spd up dest
*
ENUM Null
*
*
R/W
Digital output to signal Power speed up active.
26. 14.05 11186
Low Spd Zone dest
*
ENUM Null
*
*
R/W
Digital output to signal handling in Low Speed zone.
26. 14.06 11188
Over Load 1 dest
*
ENUM Null
*
*
R/W
Digital output to signal excessive load, threshold 1 exceeded.
26.14.07
11190
Over Load 2 dest
*
ENUM Null
*
*
R/W
Digital output to signal excessive load, threshold 2 exceeded..
26.14.08
11202
Limit switch dest
*
ENUM Null
*
*
R/W
Digital output to signal state of limit switches.
26.14.09
11204
Anti sway dest
*
ENUM Null
*
*
R/W
Digital output to signal anti sway function active.