ADV200-HC Manual
Page 45 of 55
MENU
PAR
Description
UM
Type
Default for application
11.03
1004
Enable / disable Mode
*
BOOL
OFF
11.06
1010
Comando Safe start
*
BOOL
ON
11.10
1018
Sorgente dig Enable
*
BOOL
Pad 6
11.11
1020
Sorgente dig Start
*
BOOL
Pad 3
11.17
1042
FR forward src
*
BOOL
Pad 2
11.18
1044
FR reverse src
*
BOOL
Pad 4
13.02
1312
Sorgente dig Output 2
*
BOOL
Pad 1
This parameter can be changed from default..
19.18
2310
Flux weakening OL
*
ENUM
Enable
20.13
2382
Torque Ref 1 Src
*
ENUM
Dig Torque Ref 1
21.03
2404
Voltage torque boost
*
ENUM
Enable
24.01
4500
Fault reset src
*
ENUM
null
23.08.05
5712
FL N Fwd slave chg
*
INT
0
23.08.06
5714
FL fault enable src
*
ENUM
One
23.08.02
5818
FL bidirectional
*
BOOL
Enable
23.08.03
5820
FL N of slave
*
INT
1
23.08.11
5830
FL Rev 1 src
*
ENUM
Pad 7
23.08.12
5832
FL Rev 2 src
*
ENUM
Pad 8
4.2.4
Essential steps for drive configuration
See the relative chapters for specific brake and function settings.
Descrizione
Menu \ Parametro
IPA
1
Load application default values.
H&C SERVICE \App Load default
11144
2
Specify the type of movement controlled
by the drive and its configuration (Hoist,
Trolley or Gantry) …–ELS, -HL.
HOIST&CRANE \ H&C SERVICE \ Movement type
26.02.01
11002
3
Specify type of input for speed reference
(joystick) - digital or analog.
HOIST&CRANE \ H&C SERVICE \ Jstk Speed Type
position
26.02.03
11062