g) Check that the homogenizing pressure control devices on the panel on the machine (pneumatic
switch
A
and reducer
B
STAGE 1 and switch
C
and reducer
D
STAGE 2) are completely slackened
or turned OFF.
FIG. 5.9
h) Check that all safety and protection equipment is present and operational.
i) Make sure that any valves and parts of the system downstream from the homogenizer are open